HEIGHT: |
71 feet clear
height, single tubing, double rods |
RATING: |
Maximum rated static
hook load |
|
150,000 pounds with 4 lines strung |
|
170,000 pounds with 6 lines strung |
COLUMN LEGS: |
2" x 6" x 3/16" wall
Hi-tensile tubing |
BRACES:
|
1 1/2" x 3" x 1/8"
wall Hi-tensile tubing |
BASE SECTION:
|
4-leg model (2 legs to ground, 2 legs to rear of rig) |
|
Turnbuckle tilting
with 3" screw in legs to ground |
TUBING BOARD:
|
Capacity 12,000 feet of 2" tubing |
|
Fingers for end
racking and adjustable for any size tubing |
|
Board raises and
lowers automatically with lines in tension at all times |
|
Mounts at 26 feet
above ground |
ROD BOARD: |
2 - No. 104 rod
hangers with combined capacity of 208 stands of 3/4" rods
with adapter sleeves |
|
furnished will
handle 5/8" , 3/4", 7/8" and 1" sucker rods |
|
Includes rodman basket, air cylinder transfer system and
safety sub-elevators |
|
Rod equipment goes
into position when derrick is scoped up or down |
|
Mounted at 53 feet
for double rods |
|
Installed in new
derrick |
HYDRAULICS:
|
Scoping Ram &
push-pull raising ram- chrome plated |
|
Controls for
raising, lowering and scoping derrick |
|
Operates off rig
hydraulic system |
CROWN:
|
For 4 line string up
of conventional block flat with derrick |
|
2 - 24" Single
sheaves in line |
|
1 - 24" Single
sheave cross mounted |
|
1 - 24" Sandline sheave |
|
2 - Catline sheaves |
DERRICK LOCKS: |
Top section of
derrick locks to bottom section when four load pins extend
activated by two springs. Load pins are released
manually with lever at operator's position when telescoping
up or down |
WIRE ROPE:
|
2 - Load guys with
tail chain and tightening binder |
PRIMER COAT:
|
Briner Inorganic
Zinc. |
TOP COAT:
|
Dupont
Imron or PPG Del Fleet |
WEIGHT:
|
11,800# est. |